轨道车辆车体用Q460ME钢板疲劳性能研究
DOI:
作者:
作者单位:

1.中车株洲电力机车有限公司;2.taptap点点官方注册机电与车辆工程学院

作者简介:

通讯作者:

中图分类号:

U270.12

基金项目:


Study on fatigue performance of Q460ME steel plate for rail vehicle body
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为了研究轨道车辆车体用Q460ME钢板疲劳性能,采用MTS Landmark 电液伺服疲劳试验机对Q460ME 2个厚度规格的钢板进行了应力比为-0.1,加载频率为60Hz的疲劳试验,试验基于升降法展开,通过应力集中系数修正计算得到了不同存活率下的条件疲劳极限,将测试结果与DVS1612标准进行对比,结果表明:本次试验试样的应力集中系数为1.25;Q460ME钢板2个厚度规格的试样升降图均能闭合,由升降图计算得到的疲劳极限值整体呈现随厚度增加而降低的现象,其中:5mm和8mm厚度的Q460ME疲劳强度值明显大于DVS1612标准中的S355钢材疲劳强度值;Q460ME钢板2个厚度规格试样的断口截面可见明显的裂纹源、裂纹扩展区及瞬断区,疲劳裂纹源发生于矩形截面表面拐角处且为单裂纹源,裂纹扩展区有明显的“海滩状”疲劳辉纹,整体呈扇形分布,与裂纹局部扩展方向垂直,瞬断区为韧性断裂,反映了试样良好的韧性特征。

    Abstract:

    In order to study the fatigue performance of Q460ME steel plate for rail vehicle body, MTS landmark electro-hydraulic servo fatigue testing machine was used to carry out fatigue tests on Q460ME steel plates with two thickness specifications. The stress ratio was -0.1 and theloading frequency was 60Hz. The tests were carried out based on lifting method. The conditional fatigue limit parameters under different survival rates were calculated by means of stress concentration factor correction. The test results are compared with DVS1612 standard. The results show that the stress concentration factor of the test sample is 1.25. The results show that the lifting diagrams of Q460ME steel plate with two thickness specifications can be closed, and the fatigue limit values calculated by the lifting diagram decrease with the increase of thickness, in which the fatigue strength values of Q460ME with 5mm and 8mm thickness are significantly higher than that of S355 steel in DVS1612 standard. The results show that obvious crack source, crack propagation zone and instantaneous fracture zone can be seen in the fracture section of three thickness specimens of Q460ME steel plate. The fatigue crack source occurs at the corner of the rectangular section surface and is a single crack source. There are obvious "beach" fatigue striations in the crack propagation zone, which are fan-shaped and perpendicular to the local crack propagation direction. The instantaneous fracture zone is ductile fracture which reflects the good toughness of the sample.

    参考文献
    相似文献
    引证文献
引用本文
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-08-30
  • 最后修改日期:2021-10-19
  • 录用日期:2021-10-21
  • 在线发布日期:
  • 出版日期:
Baidu
map
关闭