Abstract:In order to improve the lightning protection level of railway catenary equipment and reduce the probability of lightning shielding failure, this paper considers the size of the protection angle in the calculation of the height of the lightning conductor, deduces the mathematical relationship between the size of the protection angle and the erection position of the lightning conductor by using the geometric relationship between the protected equipment and the lightning conductor, and establishes the corresponding mathematical model. By adjusting the protection angle of lightning conductor, the probability of lightning shielding failure is reduced. Referring to the OCS data of zhunshuo railway, the lightning shielding failure probability of lines before and after adjustment is calculated and compared. It is found that the lightning shielding failure probability of lines after adjustment is reduced by 20.65%, which is close to the minimum lightning shielding failure probability calculated theoretically. This method can effectively reduce the lightning shielding failure probability without increasing the cost.